{"id":13,"date":"2026-05-27T07:01:52","date_gmt":"2026-05-27T07:01:52","guid":{"rendered":"https:\/\/www.exwellpro.com\/?p=13"},"modified":"2026-05-27T09:14:20","modified_gmt":"2026-05-27T09:14:20","slug":"electronic-detonator-module-system-description","status":"publish","type":"post","link":"https:\/\/www.exwellpro.com\/index.php\/2026\/05\/27\/electronic-detonator-module-system-description\/","title":{"rendered":"Electronic Detonator Module System Description"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><strong>1<\/strong><strong>\u3001<\/strong><strong>Electronic Detonator Module<\/strong><strong><\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Scope of Application<\/strong><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">The NKM-APH12S (NK10) industrial electronic control module is equipped with a dedicated NK10 detonator chip, serving as a high-performance control core specially designed for electronic detonators. Adopting integrated technology to achieve multiple technological breakthroughs, the module is widely applicable to various blasting operation scenarios, including open-pit blasting, tunneling blasting, demolition engineering and mining exploitation.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Technical Parameter Table<\/strong><\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td colspan=\"2\"><strong>Item<\/strong><strong><\/strong><\/td><td><strong>Parameters<\/strong><strong><\/strong><\/td><td><strong>Remarks<\/strong><strong><\/strong><\/td><\/tr><tr><td colspan=\"2\">Product Model<\/td><td>NKM-APH12S(NK10)<\/td><td>&nbsp;<\/td><\/tr><tr><td rowspan=\"2\">Dimensions<\/td><td>Outer Diameter (mm)<\/td><td>\u22646.0<\/td><td rowspan=\"2\">See drawings for details<\/td><\/tr><tr><td>Length (mm)<\/td><td>\u2264 36.8 (Excluding terminals: \u2264 33.8)<\/td><\/tr><tr><td rowspan=\"2\">Energy Storage Capacitor<\/td><td>Type<\/td><td>TG4X9-80<\/td><td>&nbsp;<\/td><\/tr><tr><td>Specifications<\/td><td>Solid-liquid hybrid capacitor&nbsp;80uF\/25V<\/td><td>&nbsp;<\/td><\/tr><tr><td rowspan=\"3\">Delay Time<\/td><td>Delay Setting Method<\/td><td>On-site programming<\/td><td>&nbsp;<\/td><\/tr><tr><td>Maximum Setting Delay<\/td><td>12000ms<\/td><td>&nbsp;<\/td><\/tr><tr><td>Minimum Setting Delay Interval<\/td><td>1ms<\/td><td>&nbsp;<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>&nbsp;<\/td><td>Delay Accuracy<\/td><td>For delay time &lt; 200 ms: error \u2264 \u00b10.75 ms- For delay time 200\u20131000 ms: relative error \u2264 \u00b11%- For delay time &gt; 1000 ms: relative error \u2264 \u00b10.5%<\/td><td>&nbsp;<\/td><\/tr><tr><td rowspan=\"4\">Electrical Parameters<\/td><td>Operating Voltage<\/td><td>&nbsp;-24V\uff5e\ufe6224V<\/td><td>\u3000<\/td><\/tr><tr><td>Operating Voltage<\/td><td>\u226430uA<\/td><td>\u3000<\/td><\/tr><tr><td>Overvoltage Protection Threshold<\/td><td>\u226528V<\/td><td>&nbsp;<\/td><\/tr><tr><td>Undervoltage Protection Threshold<\/td><td>\u22646V<\/td><td>&nbsp;<\/td><\/tr><tr><td rowspan=\"2\">Ignition Element<\/td><td>Type<\/td><td>Energetic Resistor<\/td><td>\u300060mJ<\/td><\/tr><tr><td>Resistance<\/td><td>8\u03a9 \u00b1 20%<\/td><td>Directly inserts into the primary explosive for initiation; no primer needed<\/td><\/tr><tr><td>Safety Voltage<\/td><td>Safety Voltage Range<\/td><td>Maximum non-firing current &gt; 100mA; Reliable firing voltage &lt; 15V<\/td><td>&nbsp;<\/td><\/tr><tr><td>Lead Terminal<\/td><td>Terminal Specification<\/td><td>M-thread lead terminal<\/td><td>&nbsp;<\/td><\/tr><tr><td rowspan=\"4\">Data Storage<\/td><td>BID<\/td><td>4 Byte<\/td><td>\u3000<\/td><\/tr><tr><td>UID<\/td><td>7 ByteComposed of 14-digit numbers or letters A\u2013F<\/td><td>\u3000<\/td><\/tr><tr><td>Detonation Password<\/td><td>4 ByteComposed of 8-digit numbers or letters A\u2013F<\/td><td>\u3000<\/td><\/tr><tr><td>Delay<\/td><td>2 Byte<\/td><td>\u3000<\/td><\/tr><tr><td rowspan=\"4\">Communication<\/td><td>Communication Voltage \/ Current<\/td><td>9V \/ 19mA (typical value)<\/td><td>\u3000<\/td><\/tr><tr><td>Number of Units Supported<\/td><td>500 detonators (per single blasting machine)<\/td><td>\u3000<\/td><\/tr><tr><td>Communication Distance<\/td><td>\u2264 1000 m (at 120\u03a9) \/ 10 m lead wire<\/td><td>&nbsp;<\/td><\/tr><tr><td>Variable-Frequency Communication<\/td><td>Supports variable-frequency communication to meet higher communication requirements<\/td><td>&nbsp;<\/td><\/tr><tr><td>Charging<\/td><td>Charging Voltage \/ Current<\/td><td>23V \/ 3.3mA (typical value)<\/td><td>&nbsp;<\/td><\/tr><tr><td rowspan=\"2\">Discharging<\/td><td>Active Discharge Parameters<\/td><td>The maximum charging voltage drops to \u2264 2V within 5 seconds<\/td><td>&nbsp;<\/td><\/tr><tr><td>Passive Discharge Parameters<\/td><td>The maximum charging voltage drops to \u2264 2V within 5 minutes<\/td><td>&nbsp;<\/td><\/tr><tr><td rowspan=\"3\">Compliance Standards<\/td><td>Production &amp; Inspection<\/td><td>WJ\/T 9085-2024<\/td><td>\u3000<\/td><\/tr><tr><td>Field Application<\/td><td>GB6722\u20142014<\/td><td>\u3000<\/td><\/tr><tr><td>Information Management<\/td><td>GA1531\uff0d2018<\/td><td>\u3000<\/td><\/tr><tr><td rowspan=\"4\">Operating Environment<\/td><td>Humidity<\/td><td>Relative humidity: 20% ~ 75%<\/td><td>\u3000<\/td><\/tr><tr><td>Atmospheric Pressure<\/td><td>70\uff5e106 KPa<\/td><td>\u3000<\/td><\/tr><tr><td>Operating Temperature<\/td><td>-40\u2103\uff5e85\u2103<\/td><td>\u3000<\/td><\/tr><tr><td>Storage Temperature<\/td><td>5\u2103\uff5e35\u2103<\/td><td>\u3000<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Module Image\uff1a<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" width=\"150\" height=\"44\" class=\"wp-image-16\" style=\"width: 150px;\" src=\"https:\/\/www.exwellpro.com\/wp-content\/uploads\/2026\/05\/\u6a21\u7ec4.png\" alt=\"\" srcset=\"https:\/\/www.exwellpro.com\/wp-content\/uploads\/2026\/05\/\u6a21\u7ec4.png 969w, https:\/\/www.exwellpro.com\/wp-content\/uploads\/2026\/05\/\u6a21\u7ec4-300x88.png 300w, https:\/\/www.exwellpro.com\/wp-content\/uploads\/2026\/05\/\u6a21\u7ec4-768x224.png 768w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>2<\/strong><strong>\u3001<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><strong>Blasting Machine<\/strong><\/strong><strong><strong><\/strong><\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Main Components and Interface Description<\/strong><\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"942\" height=\"561\" src=\"https:\/\/www.exwellpro.com\/wp-content\/uploads\/2026\/05\/\u8d77\u7206\u5668.png\" alt=\"\" class=\"wp-image-18\" srcset=\"https:\/\/www.exwellpro.com\/wp-content\/uploads\/2026\/05\/\u8d77\u7206\u5668.png 942w, https:\/\/www.exwellpro.com\/wp-content\/uploads\/2026\/05\/\u8d77\u7206\u5668-300x179.png 300w, https:\/\/www.exwellpro.com\/wp-content\/uploads\/2026\/05\/\u8d77\u7206\u5668-768x457.png 768w\" sizes=\"auto, (max-width: 942px) 100vw, 942px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>1\u3001Light Sensor<\/td><td>10\u3001Speaker<\/td><\/tr><tr><td>2\u3001Front Camera<\/td><td>11\u3001Blasting Control Card Compartment Cover<\/td><\/tr><tr><td>3\u3001Function Indicator Light<\/td><td>12\u3001Hand-Tightening Screw<\/td><\/tr><tr><td>4\u3001System Indicator Light<\/td><td>13\u3001Battery Compartment Cover<\/td><\/tr><tr><td>5\u3001Touch Display Area<\/td><td>14\u3001Type-C Interface<\/td><\/tr><tr><td>6\u3001Main Keyboard<\/td><td>15\u3001Cascade Interface<\/td><\/tr><tr><td>7\u3001Scanning Window<\/td><td>16\u3001Safety Switch<\/td><\/tr><tr><td>8\u3001Scanning Window<\/td><td>17\u3001Scan Button<\/td><\/tr><tr><td>9\u3001Rear Camera<\/td><td>&nbsp;<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Function Introduction<\/strong><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">After successful login, the user will directly enter the home page functional interface.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The functions on the home page are described as follows\uff1a<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"381\" height=\"594\" src=\"https:\/\/www.exwellpro.com\/wp-content\/uploads\/2026\/05\/\u8d77\u7206\u5668UI.png\" alt=\"\" class=\"wp-image-21\" srcset=\"https:\/\/www.exwellpro.com\/wp-content\/uploads\/2026\/05\/\u8d77\u7206\u5668UI.png 381w, https:\/\/www.exwellpro.com\/wp-content\/uploads\/2026\/05\/\u8d77\u7206\u5668UI-192x300.png 192w\" sizes=\"auto, (max-width: 381px) 100vw, 381px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>No.<\/strong><strong><\/strong><\/td><td><strong>Function Name<\/strong><strong><\/strong><\/td><td><strong>Description<\/strong><strong><\/strong><\/td><\/tr><tr><td>\u2460<\/td><td>Device Number<\/td><td>Displays the current device number for easy identification by the user.<\/td><\/tr><tr><td>\u2461<\/td><td>Project Management<\/td><td>Manages projects and contracts, used for blasting authorization download.<\/td><\/tr><tr><td>\u2462<\/td><td>Device Status<\/td><td>Displays the current device status (including no-load disconnection, current value, and voltage value).<\/td><\/tr><tr><td>\u2463<\/td><td>Detonator Registration<\/td><td>Scans detonators to be networked and sets their delay times.<\/td><\/tr><tr><td>\u2464<\/td><td>Network Blasting<\/td><td>Performs quantity scanning, authorization verification, charging and detonation operations on detonators to be blasted.<\/td><\/tr><tr><td>\u2465<\/td><td>Detonator Authorization<\/td><td>Downloads the authorization work code for the detonators to be blasted.<\/td><\/tr><tr><td>\u2466<\/td><td>Single Detonator Test<\/td><td>Performs functional testing on a single detonator.<\/td><\/tr><tr><td>\u2467<\/td><td>GPS Positioning<\/td><td>Displays current positioning information and compares authorized GPS coordinates to indicate allowed\/prohibited blasting areas.<\/td><\/tr><tr><td>\u2468<\/td><td>Log Feedback<\/td><td>Records the device&#8217;s operation and feedback information.<\/td><\/tr><tr><td>\u2469<\/td><td>Upload Records<\/td><td>Records and views data of completed blasting operations and uploaded data.<\/td><\/tr><tr><td>\u246a<\/td><td>Settings Center<\/td><td>Used for device upgrade operations, as well as viewing and setting other auxiliary functions.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>3<\/strong><strong>\u3001IoT Platform<\/strong><strong><\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Platform Overview<\/strong><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">The Blasting IoT Platform is a comprehensive management platform specifically designed for the blasting industry. It aims to provide accurate, efficient, and convenient digital solutions for the full life cycle of blasting operations.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The main functions of the platform include blasting enterprise management, blasting personnel management, blasting machine management, blasting record management, blasting machine version management, etc. Through full-process<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Function Overview<\/strong><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">After logging in, the user will see the following functions:<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"937\" height=\"429\" src=\"https:\/\/www.exwellpro.com\/wp-content\/uploads\/2026\/05\/IOT\u5e73\u53f0.png\" alt=\"\" class=\"wp-image-22\" srcset=\"https:\/\/www.exwellpro.com\/wp-content\/uploads\/2026\/05\/IOT\u5e73\u53f0.png 937w, https:\/\/www.exwellpro.com\/wp-content\/uploads\/2026\/05\/IOT\u5e73\u53f0-300x137.png 300w, https:\/\/www.exwellpro.com\/wp-content\/uploads\/2026\/05\/IOT\u5e73\u53f0-768x352.png 768w\" sizes=\"auto, (max-width: 937px) 100vw, 937px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>4<\/strong><strong>\u3001Core Advantages<\/strong><strong><\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Thermite-based energetic ignition resistor: <\/strong>Eliminates the primer charge in the detonator, enabling direct initiation of common primary explosives such as DDNP and lead thiocyanate series.<\/li>\n\n\n\n<li><strong>13% efficiency improvement: <\/strong>The dipping process is removed from production; the module can be directly inserted into the primary explosive.<\/li>\n\n\n\n<li><strong>20% safety improvement:<\/strong>&nbsp;Traditional primer compounds are highly sensitive and prone to accidents during production and transportation.<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>1\u3001Electronic Detonator Module The NKM-APH12S (NK10) industrial electronic control module is equipped with a dedicated&hellip;<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[5],"tags":[],"class_list":["post-13","post","type-post","status-publish","format-standard","hentry","category-detonator"],"_links":{"self":[{"href":"https:\/\/www.exwellpro.com\/index.php\/wp-json\/wp\/v2\/posts\/13","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.exwellpro.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.exwellpro.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.exwellpro.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.exwellpro.com\/index.php\/wp-json\/wp\/v2\/comments?post=13"}],"version-history":[{"count":4,"href":"https:\/\/www.exwellpro.com\/index.php\/wp-json\/wp\/v2\/posts\/13\/revisions"}],"predecessor-version":[{"id":23,"href":"https:\/\/www.exwellpro.com\/index.php\/wp-json\/wp\/v2\/posts\/13\/revisions\/23"}],"wp:attachment":[{"href":"https:\/\/www.exwellpro.com\/index.php\/wp-json\/wp\/v2\/media?parent=13"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.exwellpro.com\/index.php\/wp-json\/wp\/v2\/categories?post=13"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.exwellpro.com\/index.php\/wp-json\/wp\/v2\/tags?post=13"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}